Getting amassed treasured experience in cooperating with overseas customers, guarantees the steadiness and consistency of the important purpose of components. With numerous years’ knowledge in these traces, we have been distinguished from other suppliers in China by our rewards in competitive pricing, on-time delivery, prompt responses, on-hand engineering support and great following-product sales services.
EPT Features
one. Condensers are the very first decision of refrigeraion and AC industry. Condenser with a capacity 8kW~1800kW and surface area twenty~4100 sq. meter which has vast software assortment. It is fleXiHu (West EPT) Dis.ble to match which various dimension of compressor. Use low particular vitality consumption followers, large efficiency internal groove copper tube and sine wave EPT fin. EPTTble materials with slender but rigid enclosure hard gloss powEPTTcoated sheet metal provides corrosion proof unEPTThostile surroundings. There are best air outlet or aspect air outlet construct for C1 collection, quotV quot kind for C2 series. C2 float coil can avert refrigerant leakage effictively, it assures a durable and safety finned heat exchanger.
two. EPT performance warmth exchanger: capacity types for maXiHu (West EPT) Dis.mizing the warmth transfer relative to the vitality usage of the enthusiast. EPT and tube coupling design and style for reduced pressure fall in the coil on the media sides(maXiHu (West EPT) Dis.mum 100KPa at water planning issue). Our thermodynamic and aerodynamic planning computer software is EPTT year examined and proved in Germany
3. Supporter: only decide on minimal particular vitality usage followers. Fan nozzle patterns for maXiHu (West EPT) Dis.mum air circulation and air toss.Our followers from the world`s major manufacturer are virtually proved to be reliable in operation and EPTT long lasting. EPT: defense class IP fifty four and insulation class F. Air separator for each and every enthusiast.
four. We faXiHu (West EPT) Dis.Hu (West EPT) Dis.tate you to have a EPTT lasting and reduced maintainance procedure. EPTTble substance and rigid enclosure with hard gloss powEPTTcoated finish. Protective enclosure for each manifolds and U-bends. Unit design and style for outside installation. one hundred% leakage analyzed at 31bar.
Air discharge course |
|
Overall performance ranges |
Cooling ability: from five to 649 kw |
EPT effectiveness heat exchanger |
Ability types for maXiHu (West EPT) Dis.mizing the warmth transfer relative to the energy usage of the supporter. |
Enthusiast |
Only select reduced certain energy intake fans. |
Tests |
Heat exchangers are supplied thoroughly clean and analyzed at a pressure of 30 bars |
Possibilities |
Coil design and style refrigerant: h2o, oil, glycol. |
EPTnical parameter
Dry cooler D2 sequence parameter(fin place 2.1mm)
Type | D2-148-4×630 | D2-166-4×630 | D2-a hundred seventy five-4×630 | D2-228-6×630 | D2-250-6×630 | D2-276-6×630 | D2-310-8×630 | D2-343-8×630 | D2-364-8×630 | D2-392-10×630 | |||
Ability | JCEP | KW | 147.ninety nine | one hundred sixty five.85 | one hundred seventy five.21 | 227.85 | 250.42 | 276.53 | 309.eighty five | 342.seventy three | 364.07 | 391.ninety nine | |
twenty% Et. Glycol | KW | 142.forty two | 161.57 | one hundred seventy.91 | 219.09 | 244.69 | 270.22 | 301.18 | 333.fifty five | 354.sixty four | 383.3 | ||
Air circulation | M3/h | 76459 | 74341 | 72134 | 114686 | 111511 | 108188 | 152911 | 148675 | 144255 | 191136 | ||
Supporter | No. X phi | 2x2x630 | 2x2x630 | 2x2x630 | 2x3x630 | 2x3x630 | 2x3x630 | 2x4x630 | 2x4x630 | 2x4x630 | 2x5x630 | ||
Supporter motor 400/3N/50HZ |
A | twenty.four | twenty.4 | twenty.four | thirty.six | 30.six | 30.6 | forty.8 | 40.8 | forty.8 | 51.00 | ||
Seem strain stage | dB(A)10m | sixty four | 64 | sixty four | sixty six | 66 | 66 | sixty seven | sixty seven | 67 | 68 | ||
Dimension | L | mm | 2186 | 2186 | 2186 | 3250 | 3250 | 3250 | 4250 | 4250 | 4250 | 5250 | |
H | mm | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | ||
D | mm | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | ||
D1 | mm | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
L1 | mm | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | ||
L2 | mm | 1000 | one thousand | a thousand | a thousand | a thousand | one thousand | one thousand | 1000 | a thousand | a thousand | ||
L3 | mm | 1963 | 1963 | 1963 | 2963 | 2963 | 2963 | 3963 | 3963 | 3963 | 4963 | ||
EPTions inlet phi | mm | 2XDN50 | 2XDN65 | 2XDN65 | 2XDN65 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN100 | 2XDN100 | ||
EPTions onlet phi | mm | 2XDN50 | 2XDN65 | 2XDN65 | 2XDN65 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN100 | 2XDN100 | ||
Item excess weight(empty) | kg | 769 | 811 | 853 | 1134 | 1197 | 1261 | 1498 | 1589 | 1673 | 1864 |
Kind | D2-426-10×630 | D2-445-12×630 | D2-517-12×630 | D2-525-14×630 | D2-601-14×630 | D2-596-16×630 | D2-692-16×630 | D2-676-18×630 | D2-783-18×630 | D2-921-20×630 | |||
Capability | JCEP | KW | 426.15 | 444.seventy eight | 516.67 | 524.70 | 601.41 | 595.59 | 692.eleven | 676.02 | 783.03 | 921.23 | |
20% Et. Glycol | KW | 413.eighty five | 427.eighty three | 504.38 | 507.ninety | 586.sixteen | 572.ninety four | 676.seventy one | 653.42 | 767.64 | 905.seventy eight | ||
Air stream | M3/h | 182123 | 229377 | 218543 | 267604 | 254816 | 301325 | 290850 | 338987 | 327612 | 351663 | ||
Fan | No. X phi | 2X5X630 | 2X6X630 | 2X6X630 | 2X7X630 | 2X7X630 | 2X8X630 | 2X8X630 | 2X9X630 | 2X9X630 | 2X10X630 | ||
Fan motor four hundred/3N/50HZ |
A | fifty one.00 | sixty one.twenty | 61.twenty | seventy one.forty | seventy one.40 | 81.sixty | eighty one.60 | 91.eighty | 91.eighty | 102.00 | ||
kW | 27.fifty | 33.00 | 33.00 | 38.fifty | 38.fifty | forty four.00 | forty four.00 | 49.fifty | 49.fifty | 55.00 | |||
Seem strain amount | dB(A)10m | sixty eight | 69 | 69 | 70 | 70 | 71 | seventy one | seventy two | 72 | seventy three | ||
Dimension | L | mm | 5250 | 6250 | 6250 | 7250 | 7250 | 8250 | 8250 | 9250 | 9250 | 15710 | |
H | mm | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | ||
D | mm | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | ||
D1 | mm | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
L1 | mm | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | ||
L2 | mm | 1000 | a thousand | one thousand | a thousand | 1000 | one thousand | a thousand | 1000 | 1000 | a thousand | ||
L3 | mm | 4963 | 5963 | 5963 | 6963 | 6963 | 7963 | 7963 | 8963 | 8963 | 9963 | ||
EPTions inlet phi | mm | 2XDN100 | 2XDN100 | 2XDN100 | 2XDN100 | 2XDN125 | 2XDN125 | 2XDN125 | 2XDN125 | 2XDN125 | 4XDN1100 | ||
EPTions onlet phi | mm | 2XDN100 | 2XDN100 | 2XDN100 | 2XDN100 | 2XDN125 | 2XDN125 | 2XDN125 | 2XDN125 | 2XDN125 | 4XDN1100 | ||
Solution bodyweight(empty) | kg | 2193 | 2224 | 2617 | 2586 | 3259 | 3244 | 3728 | 3643 | 4226 | 4283 |
Application
EPTT area: procedure engineering, warmth / EPTT EPTT, EPTT technology, chemical sector, air conditioning chiller, heat transformer, smelting, and so on.. It is appropriate for all equipment which demands heat dissipation and is set up in the open air.
Product schematic diagram
Sucessful situation